Sample Description: Zinc-Nickel plated steel panel - ZnNi/TriPass ELV 3000 chromate/HydroKlad sealer (ASTM F1941-10 FE ZN Ni 8TF)
Summary:
One (1) sample was tested for Neutral Salt Spray (Fog) Testing (NSS Test) per ASTM B117-16
One (1) sample was exposed to 960 hours of continuous NSS testing
Preventative Maintenance / Calibration on this unit was completed on September 2016 and is next due by September 2017.
Completion Date: February 13, 2017
Method: ASTM B117
WB=White Blush; WC=White Corrosion; RR=Red Rust
ZnNi Plated Steel Panel
240 Hours - WB, No WC
960 Hours - No RR
Zinc Nickel vs. Cadmium Plated Ring Test
Click to download PDF of Zinc Nickel Salt Spray Test.
Test: 384 Hours of Continuous NSS (Neutral Salt Spray) testing on both Zinc Nickel (ZnNi) and Cadmium (Cd) plated rings.
Result: Zinc Nickel outperformed the cadmium plated rings. No white corrosion is present on any of the zinc nickel plated samples.
Please submit a Request for Quote form or contact us at 972-988-1999 with any questions.
|